Quadrasorb EVO / Quadrasorb SI Anton Paar Gas Sorption Analyzer — photo 1

Quadrasorb EVO / Quadrasorb SI Anton Paar Gas Sorption Analyzer

GovDealsOther📍Golden, CO

Current Bid

$160

3 bids

Time Left

1d 8h

Ends Jun 9, 2026

Seller

🏛️ National Laboratory of the Rockies – NLR, CO

Condition: As-is

Description

Anton Paar Gas Sorption Analyzer Model – Quadrasorb EVO Used / Sold as is / Condition unknown / Untested / Specs based on model search / What is pictured is what is available 1 lot of 2 General Instrument Features •Four completely independent analysis ports, each with its own dewar and dosing system •Soft close protective door with pneumatic hinges; integrated dewar covers with belt-driven lift and coolant-level sensors •Stainless steel gas pathways with metal-to-metal seals for optimal vacuum integrity •Dedicated Po (saturation vapor pressure) transducer & manifold, enabling continuous dosing without pausing measurement •BET “QuickMode™” speeds through analysis—up to 50% faster—allowing synchronous handling of samples •Dose Wizard™ flexibility: use previous sample as dosing template; QuickMode gain option ________________________________________ 🔹 Performance Specifications •Surface area range: from 0.01 m²/g to no upper limit (using N₂) •Pore size range: approximately 0.35–400 nm •Minimum relative pressure (P/P₀): down to 1 × 10⁻³ (nitrogen at 77 K) •Total pore volume & average pore size calculations, along with adsorption/desorption isotherms ________________________________________ 🔹 Micropore / Krypton Option • Optional configuration adds a 1 torr low-pressure transducer and turbo pump, enabling Krypton analysis for microporous materials and very low surface area samples ________________________________________ 🔹 Sample Handling & Throughput •Sample types: powders and porous solids, prepared by vacuum degassing (helium or nitrogen) before analysis •Can run up to four samples in parallel, with staggered start times •Microwave degassing capability up to 350 °C (as implemented in similar systems like UCL's Autosorb IQ). ________________________________________ 🔹 Data & Software •Provides adsorption/desorption isotherms, multi- and single-point BET surface area, mesopore size distributions, total pore volume, and average pore size •Operated via QuadraWin software with guided setup, analysis, graphing, and reporting •Includes advanced data reduction methods such as Quenched Solid Density Functional Theory (QSDFT) for reliable pore size distributions Quantachrome Instruments Analyzer Surface Area Pore Size Model – Quadrasorb SI General Features •Purpose: Measures surface area, pore volume, and pore size distribution using gas adsorption techniques (BET, BJH methods). •Analysis Ports: Up to four independent stations for simultaneous measurements. •Measurement Techniques: Patented NOVA helium-free method Classical helium void-volume method •Adsorbates: Nitrogen, argon, carbon dioxide, krypton, and other non-corrosive gases. •Software: Windows®-based QuadraWin™ for instrument control and data analysis ________________________________________ Performance Specifications •Surface Area Range: Nitrogen: 0.01 m²/g to no upper limit Krypton (KR/MP model): 0.005 m²/g to no upper limit • Pore Size Range: 3.5 ∠st; to >4000 ∠st; (0.35 nm to >400 nm) •Minimum Pore Volume: Liquid: 2 × 10⁻⁶ cc/g STP: 0.0001 cc/g •Pressure Resolution: 0.016 torr (1000 torr range) 0.000016 torr (1 torr range for KR/MP model) •Ultimate Vacuum: Standard: <1 × 10⁻² torr KR/MP model: <1 × 10⁻⁹ torr with turbomolecular pump •Coolant Control: Automatic level sensor for Dewar flasks ________________________________________ Special Options •KR/MP Model: For low surface area and micropore measurements, includes low-pressure sensor and turbo-molecular vacuum pump •Gas Dosing Methods: MaxiDose™ (adaptive dosing) Constant Dose Volume (0.1–10 cc per point) Delta Volume™ (adds points in high uptake regions) ________________________________________ Applications •Catalysts, ceramics, pharmaceuticals, powdered metals, zeolites, activated carbons, molecular sieves, and other porous materials.

Pickup Information

📍
Golden, CO 80403-1949

National Laboratory of the Rockies – NLR, CO

📅Pickup within 10 business days
📝Contact seller through GovDeals for pickup details. Most sellers require pickup within 10 business days of payment.

Get notified about new other auctions like this

Free email alerts — we'll let you know when matching auctions are listed.

Similar Auctions

See all Other in Colorado

64 more live other auctions

Browse all →